<?xml version="1.0" encoding="UTF-8"?>
<xs:schema
  xmlns="https://epbr.digital.communities.gov.uk/xsd/sap"
  xmlns:xs="http://www.w3.org/2001/XMLSchema"
  targetNamespace="https://epbr.digital.communities.gov.uk/xsd/sap"
  elementFormDefault="qualified"
  attributeFormDefault="unqualified"
  version="BRUKLD-10.2"
>
	<xs:simpleType name="SAP-StoreyFloorCode">
		<xs:annotation>
			<xs:documentation>Code which identifies a particular storey in a building part.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="-1">
				<xs:annotation>
					<xs:documentation>Lower ground</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="0">
				<xs:annotation>
					<xs:documentation>Ground</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>1st</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>2nd</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>3rd</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>4th</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="5">
				<xs:annotation>
					<xs:documentation>5th</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="6">
				<xs:annotation>
					<xs:documentation>6th</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="99">
				<xs:annotation>
					<xs:documentation>Roof rooms</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-ImprovementMeasureCode">
		<xs:annotation>
			<xs:documentation>Code which indicates an improvement measure for a property.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="A">
				<xs:annotation>
					<xs:documentation>Loft insulation</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="A2">
				<xs:annotation>
					<xs:documentation>Flat roof insulation</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="A3">
				<xs:annotation>
					<xs:documentation>Room-in-roof insulation</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="B">
				<xs:annotation>
					<xs:documentation>Cavity wall insulation</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="C">
				<xs:annotation>
					<xs:documentation>Hot water cylinder insulation</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="D">
				<xs:annotation>
					<xs:documentation>Draughtproofing</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="E">
				<xs:annotation>
					<xs:documentation>Low energy lights</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="F">
				<xs:annotation>
					<xs:documentation>Cylinder thermostat</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="G">
				<xs:annotation>
					<xs:documentation>Heating controls for wet central heating system</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="H">
				<xs:annotation>
					<xs:documentation>Heating controls for warm air system</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="I">
				<xs:annotation>
					<xs:documentation>Upgrade boiler, same fuel</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="J">
				<xs:annotation>
					<xs:documentation>Biomass boiler</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="J2">
				<xs:annotation>
					<xs:documentation>Biomass boiler as alternative improvement</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="K">
				<xs:annotation>
					<xs:documentation>Biomass room heater with boiler</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="L">
				<xs:annotation>
					<xs:documentation>New or replacement fan-assisted storage heaters</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="L2">
				<xs:annotation>
					<xs:documentation>New or replacement high heat retention storage heaters</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="M">
				<xs:annotation>
					<xs:documentation>Replacement warm-air unit</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="N">
				<xs:annotation>
					<xs:documentation>Solar water heating</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="O">
				<xs:annotation>
					<xs:documentation>Replacement double glazed windows</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="O3">
				<xs:annotation>
					<xs:documentation>Replacement double glazing units</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="P">
				<xs:annotation>
					<xs:documentation>Secondary glazing</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="Q">
				<xs:annotation>
					<xs:documentation>Solid wall insulation</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="Q2">
				<xs:annotation>
					<xs:documentation>External insulation with cavity wall insulation</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="R">
				<xs:annotation>
					<xs:documentation>Condensing oil boiler</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="S">
				<xs:annotation>
					<xs:documentation>Change heating to Band A gas condensing boiler (no fuel switch)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="T">
				<xs:annotation>
					<xs:documentation>Change heating to Band A gas condensing boiler (fuel switch)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="T2">
				<xs:annotation>
					<xs:documentation>Flue gas heat recovery</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="U">
				<xs:annotation>
					<xs:documentation>Photovoltaics</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="V">
				<xs:annotation>
					<xs:documentation>Wind turbine (roof mounted)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="V2">
				<xs:annotation>
					<xs:documentation>Wind turbine (on mast)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="W">
				<xs:annotation>
					<xs:documentation>Floor insulation</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="X">
				<xs:annotation>
					<xs:documentation>Insulated doors</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="Y">
				<xs:annotation>
					<xs:documentation>Instantaneous waste water heat recovery</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="Y2">
				<xs:annotation>
					<xs:documentation>Storage waste water heat recovery</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="Z1">
				<xs:annotation>
					<xs:documentation>Air or ground source heat pump</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="Z2">
				<xs:annotation>
					<xs:documentation>Air or ground source heat pump with underfloor heating</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="Z3">
				<xs:annotation>
					<xs:documentation>Micro-CHP</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-WaterHeatingCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the type of heating system, as defined in SAP table 4a (codes 901-999).</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:positiveInteger">
			<xs:maxInclusive value="999"/>
			<xs:minInclusive value="901"/>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-LZCEnergySourceCode">
		<xs:annotation>
			<xs:documentation>Code which indicates a particular low or zero carbon energy source.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>Biofuel main heating</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>Biofuel community heating</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>Biofuel community heating for some of heat generation</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>Biofuel secondary heating</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="5">
				<xs:annotation>
					<xs:documentation>Geothermal heat source</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="6">
				<xs:annotation>
					<xs:documentation>Community combined heat and power</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="7">
				<xs:annotation>
					<xs:documentation>Ground source heat pump</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="8">
				<xs:annotation>
					<xs:documentation>Water source heat pump</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="9">
				<xs:annotation>
					<xs:documentation>Air source heat pump</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="10">
				<xs:annotation>
					<xs:documentation>Solar water heating</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="11">
				<xs:annotation>
					<xs:documentation>Solar photovoltaics</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="12">
				<xs:annotation>
					<xs:documentation>Wind turbine</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="13">
				<xs:annotation>
					<xs:documentation>Community heat pump</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="14">
				<xs:annotation>
					<xs:documentation>Hydro-electric generation</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="15">
				<xs:annotation>
					<xs:documentation>Micro-CHP</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="16">
				<xs:annotation>
					<xs:documentation>Exhaust air heat pump</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="17">
				<xs:annotation>
					<xs:documentation>Solar-assisted heat pump</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="FlueTypeCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the type of flue.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>open flue</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>balanced flue</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>chimney</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>omitted (boiler is in an outhouse, so its flue arrangements are not relevant)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="5">
				<xs:annotation>
					<xs:documentation>unknown (there is a flue, but its type could not be determined)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-GlazingGapTypeCode">
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>6 mm</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>12 mm</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>16 mm or more</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-DataTypeCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the type of SAP data.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>new dwelling as designed</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>new dwelling as built</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>new extension to existing dwelling</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>new dwelling created by change of use</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="5">
				<xs:annotation>
					<xs:documentation>existing dwelling</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="6">
				<xs:annotation>
					<xs:documentation>other</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-VersionCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the SAP version.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="9.80">
				<xs:annotation>
					<xs:documentation>SAP 2005 version 9.80, dated October 2005</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="9.81">
				<xs:annotation>
					<xs:documentation>SAP version 9.81, dated January 2008</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="9.82">
				<xs:annotation>
					<xs:documentation>SAP version 9.82, dated Jun 2008</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="9.83">
				<xs:annotation>
					<xs:documentation>SAP version 9.83, dated Jun 2009</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="9.90">
				<xs:annotation>
					<xs:documentation>SAP version 9.90, dated Mar 2010</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="9.91">
				<xs:annotation>
					<xs:documentation>SAP version 9.91, dated Jan 2012</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="9.92">
				<xs:annotation>
					<xs:documentation>SAP version 9.92, dated Oct 2013</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="10.2">
				<xs:annotation>
					<xs:documentation>SAP version 10.2, dated Oct 2020</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-FloorTypeCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the type of floor (exposure).</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>basement floor</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>ground floor</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>upper floor (if heat loss area &gt; 0, this area is an exposed floor)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>party floor</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="UKCountryCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the country within the UK, taken from BS 6879.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="EAW">
				<xs:annotation>
					<xs:documentation>England and Wales, for backwards compatibility only.</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="ENG">
				<xs:annotation>
					<xs:documentation>England</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="WLS">
				<xs:annotation>
					<xs:documentation>Wales</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="SCT">
				<xs:annotation>
					<xs:documentation>Scotland</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="NIR">
				<xs:annotation>
					<xs:documentation>Northern Ireland</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="UKRegionCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the region within the UK.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>Borders</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>East Anglia</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>East Pennines</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>East Scotland</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="5">
				<xs:annotation>
					<xs:documentation>Highland</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="6">
				<xs:annotation>
					<xs:documentation>Midlands</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="7">
				<xs:annotation>
					<xs:documentation>North East England</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="8">
				<xs:annotation>
					<xs:documentation>North East Scotland</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="9">
				<xs:annotation>
					<xs:documentation>North West England / South West Scotland</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="10">
				<xs:annotation>
					<xs:documentation>Northern Ireland</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="11">
				<xs:annotation>
					<xs:documentation>Orkney</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="12">
				<xs:annotation>
					<xs:documentation>Severn Valley</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="13">
				<xs:annotation>
					<xs:documentation>Shetland</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="14">
				<xs:annotation>
					<xs:documentation>South East England</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="15">
				<xs:annotation>
					<xs:documentation>South West England</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="16">
				<xs:annotation>
					<xs:documentation>Southern England</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="17">
				<xs:annotation>
					<xs:documentation>Thames Valley</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="18">
				<xs:annotation>
					<xs:documentation>Wales</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="19">
				<xs:annotation>
					<xs:documentation>West Pennines</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="20">
				<xs:annotation>
					<xs:documentation>West Scotland</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="21">
				<xs:annotation>
					<xs:documentation>Western Isles</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="22">
				<xs:annotation>
					<xs:documentation>Jersey</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="23">
				<xs:annotation>
					<xs:documentation>Guernsey</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="24">
				<xs:annotation>
					<xs:documentation>Isle of Man</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-WallTypeCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the type of wall (exposure).</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>basement wall</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>exposed wall</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>sheltered wall</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>party wall</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="5">
				<xs:annotation>
					<xs:documentation>internal wall</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-ThermalBridgeCode">
		<xs:annotation>
			<xs:documentation>Code which indicates how the thermal bridge data has been recorded.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>default</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>2002 regulations. For backwards compatibility only, do not use.</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>accredited. For backwards compatibility only, do not use.</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>user defined (global y-value)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="5">
				<xs:annotation>
					<xs:documentation>user defined (individual values)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-ThermalBridgeTypeCode">
		<xs:annotation>
			<xs:documentation>Code which indicates a particular type of thermal bridge.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="ND">
				<xs:annotation>
					<xs:documentation>not defined (for backward compatibility only, do not use)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="E1">
				<xs:annotation>
					<xs:documentation>Steel lintel with perforated steel base plate</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="E2">
				<xs:annotation>
					<xs:documentation>Other lintels (including other steel lintels)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="E3">
				<xs:annotation>
					<xs:documentation>Sill</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="E4">
				<xs:annotation>
					<xs:documentation>Jamb</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="E5">
				<xs:annotation>
					<xs:documentation>Ground floor (normal)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="E6">
				<xs:annotation>
					<xs:documentation>Intermediate floor within a dwelling</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="E7">
				<xs:annotation>
					<xs:documentation>Party floor between dwellings (in blocks of flats)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="E8">
				<xs:annotation>
					<xs:documentation>Balcony within a dwelling, wall insulation continuous</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="E9">
				<xs:annotation>
					<xs:documentation>Balcony between dwellings, wall insulation continuous</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="E10">
				<xs:annotation>
					<xs:documentation>Eaves (insulation at ceiling level)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="E11">
				<xs:annotation>
					<xs:documentation>Eaves (insulation at rafter level)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="E12">
				<xs:annotation>
					<xs:documentation>Gable (insulation at ceiling level)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="E13">
				<xs:annotation>
					<xs:documentation>Gable (insulation at rafter level)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="E14">
				<xs:annotation>
					<xs:documentation>Flat roof</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="E15">
				<xs:annotation>
					<xs:documentation>Flat roof with parapet</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="E16">
				<xs:annotation>
					<xs:documentation>Corner (normal)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="E17">
				<xs:annotation>
					<xs:documentation>Corner (inverted – internal area greater than external area)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="E18">
				<xs:annotation>
					<xs:documentation>Party wall between dwellings</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="E19">
				<xs:annotation>
					<xs:documentation>Ground floor (inverted)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="E20">
				<xs:annotation>
					<xs:documentation>Exposed floor (normal)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="E21">
				<xs:annotation>
					<xs:documentation>Exposed floor (inverted)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="E22">
				<xs:annotation>
					<xs:documentation>Basement floor</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="E23">
				<xs:annotation>
					<xs:documentation>Balcony within or between dwellings, balcony support penetrates wall insulation</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="E24">
				<xs:annotation>
					<xs:documentation>Eaves (insulation at ceiling level – inverted)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="E25">
				<xs:annotation>
					<xs:documentation>Staggered party wall between dwellings</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="P1">
				<xs:annotation>
					<xs:documentation>Ground floor</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="P2">
				<xs:annotation>
					<xs:documentation>Intermediate floor within a dwelling</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="P3">
				<xs:annotation>
					<xs:documentation>Intermediate floor between dwellings (in blocks of flats)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="P4">
				<xs:annotation>
					<xs:documentation>Roof (insulation at ceiling level)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="P5">
				<xs:annotation>
					<xs:documentation>Roof (insulation at rafter level)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="P6">
				<xs:annotation>
					<xs:documentation>Ground floor (inverted)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="P7">
				<xs:annotation>
					<xs:documentation>Exposed floor (normal)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="P8">
				<xs:annotation>
					<xs:documentation>Exposed floor (inverted)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="R1">
				<xs:annotation>
					<xs:documentation>Head of roof window</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="R2">
				<xs:annotation>
					<xs:documentation>Sill of roof window</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="R3">
				<xs:annotation>
					<xs:documentation>Jamb of roof window</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="R4">
				<xs:annotation>
					<xs:documentation>Ridge (vaulted ceiling)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="R5">
				<xs:annotation>
					<xs:documentation>Ridge (inverted)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="R6">
				<xs:annotation>
					<xs:documentation>Flat ceiling</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="R7">
				<xs:annotation>
					<xs:documentation>Flat ceiling (inverted)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="R8">
				<xs:annotation>
					<xs:documentation>Roof to wall (rafter)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="R9">
				<xs:annotation>
					<xs:documentation>Roof to wall (flat ceiling)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="R10">
				<xs:annotation>
					<xs:documentation>All other roof or room-in-roof junctions</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="R11">
				<xs:annotation>
					<xs:documentation>Upstands or kerbs of rooflights</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="O1">
				<xs:annotation>
					<xs:documentation>other type 1</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="O2">
				<xs:annotation>
					<xs:documentation>other type 2</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-OrientationCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the compass direction.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="0">
				<xs:annotation>
					<xs:documentation>unknown or unspecified</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>North</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>North East</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>East</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>South East</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="5">
				<xs:annotation>
					<xs:documentation>South</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="6">
				<xs:annotation>
					<xs:documentation>South West</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="7">
				<xs:annotation>
					<xs:documentation>West</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="8">
				<xs:annotation>
					<xs:documentation>North West</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="9">
				<xs:annotation>
					<xs:documentation>Horizontal (windows and roof windows only)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-OpeningDataSourceCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the source of opening data.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>manufacturer declaration</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>SAP table</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>BFRC data</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-OpeningTypeCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the type of opening.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>solid door</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>semi-glazed door</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>door to corridor</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>window</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="5">
				<xs:annotation>
					<xs:documentation>roof window</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="6">
				<xs:annotation>
					<xs:documentation>rooflight</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="HeatEmitterCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the type of heating emitter.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>radiators</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>underfloor</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>both radiators and underfloor</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>fan coil units</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-GlazingTypeCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the type of glazing; if U-value is from BFRC or manufacturer declaration, give as one of
- single
- double
- triple.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>not applicable (non-glazed door)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>single</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>double</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>double low-E hard 0.2</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="5">
				<xs:annotation>
					<xs:documentation>double low-E hard 0.15</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="6">
				<xs:annotation>
					<xs:documentation>double low-E soft 0.1</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="7">
				<xs:annotation>
					<xs:documentation>double low-E soft 0.05</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="8">
				<xs:annotation>
					<xs:documentation>triple</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="9">
				<xs:annotation>
					<xs:documentation>triple low-E hard 0.2</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="10">
				<xs:annotation>
					<xs:documentation>triple low-E hard 0.15</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="11">
				<xs:annotation>
					<xs:documentation>triple low-E soft 0.1</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="12">
				<xs:annotation>
					<xs:documentation>triple low-E soft 0.05</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="13">
				<xs:annotation>
					<xs:documentation>secondary glazing</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-FrameTypeCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the type of opening frame.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>wood</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>PVC</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>metal no break</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>metal 4 mm break</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="5">
				<xs:annotation>
					<xs:documentation>metal 8 mm break</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="6">
				<xs:annotation>
					<xs:documentation>metal 12 mm break</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="7">
				<xs:annotation>
					<xs:documentation>metal 20 mm break</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="8">
				<xs:annotation>
					<xs:documentation>metal 32 mm break</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="9">
				<xs:annotation>
					<xs:documentation>unknown</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-WindowOvershadingCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the amount of window overshading.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>very little</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>average or unknown</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>more than average</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>heavy</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-ConservatoryTypeCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the type of conservatory.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>no conservatory</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>separated unheated conservatory</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>separated heated conservatory</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>not separated</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-PressureTestCode">
		<xs:annotation>
			<xs:documentation>Code which indicates whether a pressure test has been done, or whether an assumed value is used.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>yes (new dwelling, value measured in this dwelling)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>yes (new dwelling, design value)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>no test, value assumed for calculation (new dwelling)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>no test, SAP algorithm used (existing dwelling)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="5">
				<xs:annotation>
					<xs:documentation>average for other dwellings of the same type (new dwelling)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="6">
				<xs:annotation>
					<xs:documentation>yes (existing dwelling)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="7">
				<xs:annotation>
					<xs:documentation>yes (measured value) - low-pressure pulse</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-CommunityHeatingUseCode">
		<xs:annotation>
			<xs:documentation>Code which indicates what kind of heating a community heating system is used for.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>space heating only</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>water heating only</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>space and water heating</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-FlatLevelCode">
		<xs:annotation>
			<xs:documentation>Codes which indicates where a flat is located within a building.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="0">
				<xs:annotation>
					<xs:documentation>basement</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>ground floor</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>mid floor</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>top floor</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-FloorConstructionCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the type of floor construction.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>not suspended timber</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>suspended timber, sealed</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>suspended timber, unsealed</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-WallConstructionCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the type of wall construction.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>steel or timber frame</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>other</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-VentilationTypeCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the type of ventilation.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>natural with intermittent extract fans</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>natural with passive vents</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>positive input from loft</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>positive input from outside</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="5">
				<xs:annotation>
					<xs:documentation>mechanical extract, centralised (MEV c)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="6">
				<xs:annotation>
					<xs:documentation>mechanical extract, decentralised (MEV dc)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="7">
				<xs:annotation>
					<xs:documentation>balanced without heat recovery (MV)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="8">
				<xs:annotation>
					<xs:documentation>balanced with heat recovery (MVHR)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="9">
				<xs:annotation>
					<xs:documentation>natural with intermittent extract fans and/or passive vents.  For backwards compatibility only, do not use.</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="10">
				<xs:annotation>
					<xs:documentation>natural with intermittent extract fans and passive vents</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-DataSourceCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the source of SAP data.  Applies to both ventilation and heating.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>from database</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>from manufacturer declaration</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>from SAP table</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-DuctTypeCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the type of duct.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>flexible</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>rigid</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>semi-rigid</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-DuctInsulationCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the type of duct insulation.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>not insulated</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>insulated</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-DuctInsulationLevel">
		<xs:annotation>
			<xs:documentation>Code which indicates the level of duct insulation.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>level 1</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>level 2</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-DuctPlacement">
		<xs:annotation>
			<xs:documentation>Code which indicates the duct placement.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>inside heated envelope</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>outside heated envelope</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>	
	<xs:simpleType name="SAP-GasOrOilBoilerTypeCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the type of boiler for the case where the fuel is gas or oil.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>regular</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>combi</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>CPSU</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>range cooker</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-CombiBoilerTypeCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the type of combi boiler.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>instantaneous, no store or keep hot</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>primary storage</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>secondary storage</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>CPSU</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="5">
				<xs:annotation>
					<xs:documentation>untimed keep-hot by fuel</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="6">
				<xs:annotation>
					<xs:documentation>timed keep hot by fuel</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="7">
				<xs:annotation>
					<xs:documentation>untimed keep-hot by electricity</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="8">
				<xs:annotation>
					<xs:documentation>timed keep hot by electricity</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="9">
				<xs:annotation>
					<xs:documentation>untimed keep-hot by fuel and electricity</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="10">
				<xs:annotation>
					<xs:documentation>timed keep hot by fuel and electricity</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-HeatingControlCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the type of heating control, as described in SAP table 4e.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:positiveInteger">
			<xs:maxInclusive value="2999"/>
			<xs:minInclusive value="2001"/>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="UnderfloorHeatEmitterCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the type of underfloor heat emitter.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>in concrete slab</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>in screed above insulation</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>in timber floor</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-BoilerFuelFeedCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the type of boiler fuel feed.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>gravity</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>manual</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>screw</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>other</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-CHPElectricityGenerationCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the CHP Electricity generation option (table 12f).</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="81">
				<xs:annotation>
					<xs:documentation>New CHP, export only.</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="82">
				<xs:annotation>
					<xs:documentation>New CHP, flexible operation.</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="83">
				<xs:annotation>
					<xs:documentation>New CHP, standard.</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="84">
				<xs:annotation>
					<xs:documentation>Existing CHP (2015+), export only.</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="85">
				<xs:annotation>
					<xs:documentation>Existing CHP (2015+), flexible operation.</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="86">
				<xs:annotation>
					<xs:documentation>Existing CHP (2015+),standard.</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="87">
				<xs:annotation>
					<xs:documentation>Existing CHP (pre-2015), export only.</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="88">
				<xs:annotation>
					<xs:documentation>Existing CHP (pre-2015), flexible operation.</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="89">
				<xs:annotation>
					<xs:documentation>Existing CHP (pre-2015), standard.</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-NonDatabaseSourceCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the source of SAP data.  Like "SAP-DataSourceCode", but without the "database" option.  This is why the enumeration doesn't start at "1".</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>from manufacturer declaration</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>from SAP table</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-ThermalStoreCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the type of thermal store.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>none</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>hot water only</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>integrated</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-HeatingDistributionCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the type of heating distribution system.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="5">
				<xs:annotation>
					<xs:documentation>calculated</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="6">
				<xs:annotation>
					<xs:documentation>unknown</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="7">
				<xs:annotation>
					<xs:documentation>Network not compliant with Code of Practice</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="8">
				<xs:annotation>
					<xs:documentation>Network compliant with Code of Practice</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-BuiltFormCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the form in which a property is built.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>Detached</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>Semi-Detached</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>End-Terrace</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>Mid-Terrace</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="5">
				<xs:annotation>
					<xs:documentation>Enclosed End-Terrace</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="6">
				<xs:annotation>
					<xs:documentation>Enclosed Mid-Terrace</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-SolarCollectorTypeCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the type of solar collector.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>unglazed</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>flat panel</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>evacuated tube</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="ND">
				<xs:annotation>
					<xs:documentation>for backwards compatability only; do not use</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-SolarCollectorDataSourceCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the source of solar collector data.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>default</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>declared values</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="ND">
				<xs:annotation>
					<xs:documentation>for backwards compatability only; do not use</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-CompassDirectionCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the compass direction.  Like SAP-OrientationCode, but without the "unknown" and "horizontal" options.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>North</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>North East</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>East</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>South East</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="5">
				<xs:annotation>
					<xs:documentation>South</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="6">
				<xs:annotation>
					<xs:documentation>South West</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="7">
				<xs:annotation>
					<xs:documentation>West</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="8">
				<xs:annotation>
					<xs:documentation>North West</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="ND">
				<xs:annotation>
					<xs:documentation>To be used when the pitch is horizontal</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="NR">
				<xs:annotation>
					<xs:documentation>not recorded – for backwards compatibility only; do not use</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-VerticalPitchCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the vertical pitch (angle).</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>horizontal</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>30 degrees</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>45 degrees</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>60 degrees</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="5">
				<xs:annotation>
					<xs:documentation>vertical</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-SolarCollectorOvershadingCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the amount of solar collector overshading.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>none or very little</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>modest</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>significant</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>heavy</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="5">
				<xs:annotation>
					<xs:documentation>severe</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="ND">
				<xs:annotation>
					<xs:documentation>for backwards compatability only; do not use</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="HotWaterStoreInsulationTypeCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the type of hot water storage insulation.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>factory-applied</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>loose jacket</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="HeatingFuelTypeCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the type of heating fuel, as defined in SAP table 12.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>Gas: mains gas</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>Gas: bulk LPG</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>Gas: bottled LPG</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>Oil: heating oil</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="5">
				<xs:annotation>
					<xs:documentation>Gas: bottled LPG, secondary</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="7">
				<xs:annotation>
					<xs:documentation>Gas: biogas</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="8">
				<xs:annotation>
					<xs:documentation>LNG</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="9">
				<xs:annotation>
					<xs:documentation>LPG subject to Special Condition 18</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="10">
				<xs:annotation>
					<xs:documentation>Solid fuel: dual fuel appliance (mineral and wood)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="11">
				<xs:annotation>
					<xs:documentation>Solid fuel: house coal</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="12">
				<xs:annotation>
					<xs:documentation>Solid fuel: manufactured smokeless fuel</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="15">
				<xs:annotation>
					<xs:documentation>Solid fuel: anthracite</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="20">
				<xs:annotation>
					<xs:documentation>Solid fuel: wood logs</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="21">
				<xs:annotation>
					<xs:documentation>Solid fuel: wood chips</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="22">
				<xs:annotation>
					<xs:documentation>Solid fuel: wood pellets (in bags, for secondary heating)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="23">
				<xs:annotation>
					<xs:documentation>Solid fuel: wood pellets (bulk supply in bags, for main heating)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="36">
				<xs:annotation>
					<xs:documentation>Electricity: electricity sold to grid</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="37">
				<xs:annotation>
					<xs:documentation>Electricity: electricity displaced from grid</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="39">
				<xs:annotation>
					<xs:documentation>Electricity: electricity, unspecified tariff</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="41">
				<xs:annotation>
					<xs:documentation>Community heating schemes: heat from electric heat pump</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="42">
				<xs:annotation>
					<xs:documentation>Community heating schemes: heat from boilers - waste combustion</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="43">
				<xs:annotation>
					<xs:documentation>Community heating schemes: heat from boilers - biomass</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="44">
				<xs:annotation>
					<xs:documentation>Community heating schemes: heat from boilers - biogas</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="45">
				<xs:annotation>
					<xs:documentation>Community heating schemes: waste heat from power stations</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="46">
				<xs:annotation>
					<xs:documentation>Community heating schemes: geothermal heat source</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="48">
				<xs:annotation>
					<xs:documentation>Community heating schemes: heat from CHP</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="49">
				<xs:annotation>
					<xs:documentation>Community heating schemes: electricity generated by CHP</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="50">
				<xs:annotation>
					<xs:documentation>Community heating schemes: electricity for pumping in distribution network</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="51">
				<xs:annotation>
					<xs:documentation>Community heating schemes: heat from mains gas</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="52">
				<xs:annotation>
					<xs:documentation>Community heating schemes: heat from LPG</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="53">
				<xs:annotation>
					<xs:documentation>Community heating schemes: heat from oil</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="54">
				<xs:annotation>
					<xs:documentation>Community heating schemes: heat from coal</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="55">
				<xs:annotation>
					<xs:documentation>Community heating schemes: heat from B30D</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="56">
				<xs:annotation>
					<xs:documentation>Community heating schemes: heat from boilers that can use mineral oil or biodiesel</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="57">
				<xs:annotation>
					<xs:documentation>Community heating schemes: heat from boilers using biodiesel from any biomass source</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="58">
				<xs:annotation>
					<xs:documentation>Community heating schemes: biodiesel from vegetable oil only</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="71">
				<xs:annotation>
					<xs:documentation>biodiesel from any biomass source</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="72">
				<xs:annotation>
					<xs:documentation>biodiesel from used cooking oil only</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="73">
				<xs:annotation>
					<xs:documentation>biodiesel from vegetable oil only</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="74">
				<xs:annotation>
					<xs:documentation>appliances able to use mineral oil or liquid biofuel</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="75">
				<xs:annotation>
					<xs:documentation>B30K</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="76">
				<xs:annotation>
					<xs:documentation>bioethanol from any biomass source</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="99">
				<xs:annotation>
					<xs:documentation>Fuel data from pcdb</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="ColdWaterSourceCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the source of the cold water.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>mains</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>header tank</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>		
	<xs:simpleType name="ImmersionHeatingTypeCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the type of immersion heater.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>Dual</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>Single</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-SpaceHeatingCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the type of heating system, as defined in SAP tables 4a/4b (codes 101 to 899).</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:positiveInteger">
			<xs:maxInclusive value="899"/>
			<xs:minInclusive value="101"/>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-TerrainTypeCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the type of terrain.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>urban</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>suburban</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>rural</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-ElectricityTariffCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the type of electricity tariff.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>standard tariff</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>off-peak 7 hour</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>off-peak 10 hour</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>24 hour</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="5">
				<xs:annotation>
					<xs:documentation>off-peak 18 hour</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="ND">
				<xs:annotation>
					<xs:documentation>not applicable</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-MainHeatingCategoryCode">
		<xs:annotation>
			<xs:documentation>Codes used to indicate a category of main heating system.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>none</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>boiler with radiators or underfloor heating</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>micro-cogeneration</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>heat pump with radiators or underfloor heating</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="5">
				<xs:annotation>
					<xs:documentation>heat pump with warm air distribution</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="6">
				<xs:annotation>
					<xs:documentation>community heating system</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="7">
				<xs:annotation>
					<xs:documentation>electric storage heaters</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="8">
				<xs:annotation>
					<xs:documentation>electric underfloor heating</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="9">
				<xs:annotation>
					<xs:documentation>warm air system (not heat pump)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="10">
				<xs:annotation>
					<xs:documentation>room heaters</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="11">
				<xs:annotation>
					<xs:documentation>other system</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-SecondaryHeatingCategoryCode">
		<xs:annotation>
			<xs:documentation>Codes used to indicate a category of secondary heating system.  Codes are aligned with those of 'SAP-MainHeatingCategoryCode'.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>none</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="10">
				<xs:annotation>
					<xs:documentation>room heaters</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-SolidFuelBoilerType">
		<xs:annotation>
			<xs:documentation>Code which indicates the type of boiler for the case where the fuel is solid.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>independent</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>open fire</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>closed room heater</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>range cooker</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="ConstructionDateCode">
		<xs:restriction base="xs:string">
			<xs:enumeration value="A">
				<xs:annotation>
					<xs:documentation>England and Wales: before 1900;
Scotland: before 1919;
Northern Ireland: before 1919</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="B">
				<xs:annotation>
					<xs:documentation>England and Wales: 1900-1929;
Scotland: 1919-1929;
Northern Ireland: 1919-1929</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="C">
				<xs:annotation>
					<xs:documentation>England and Wales: 1930-1949;
Scotland: 1930-1949;
Northern Ireland: 1930-1949</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="D">
				<xs:annotation>
					<xs:documentation>England and Wales: 1950-1966;
Scotland: 1950-1964;
Northern Ireland: 1950-1973</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="E">
				<xs:annotation>
					<xs:documentation>England and Wales: 1967-1975;
Scotland: 1965-1975;
Northern Ireland: 1974-1977</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="F">
				<xs:annotation>
					<xs:documentation>England and Wales: 1976-1982;
Scotland: 1976-1983;
Northern Ireland: 1978-1985</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="G">
				<xs:annotation>
					<xs:documentation>England and Wales: 1983-1990;
Scotland: 1984-1991;
Northern Ireland: 1986-1991</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="H">
				<xs:annotation>
					<xs:documentation>England and Wales: 1991-1995;
Scotland: 1992-1998;
Northern Ireland: 1992-1999</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="I">
				<xs:annotation>
					<xs:documentation>England and Wales: 1996-2002;
Scotland: 1999-2002;
Northern Ireland: 2000-2006</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="J">
				<xs:annotation>
					<xs:documentation>England and Wales: 2003-2006;
Scotland: 2003-2007;
Northern Ireland: not applicable</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="K">
				<xs:annotation>
					<xs:documentation>England and Wales: 2007-2011;
Scotland: 2008-2011;
Northern Ireland: 2007-2013</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="L">
				<xs:annotation>
					<xs:documentation>England and Wales: 2012 onwards;
Scotland: 2012 onwards;
Northern Ireland: 2014 onwards</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="PsiValueSourceCode">
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>calculated by person with suitable expertise</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>government-approved scheme</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>not government-approved scheme</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>SAP table default</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="DesignWaterUseCode">
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>&lt;= 125 litres per person per day</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-CoolingSystemTypeCode">
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>split or multi-split</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>packaged</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-CoolingSystemClassCode">
		<xs:restriction base="xs:string">
			<xs:enumeration value="A+++"/>
			<xs:enumeration value="A++"/>
			<xs:enumeration value="A+"/>
			<xs:enumeration value="A"/>
			<xs:enumeration value="B"/>
			<xs:enumeration value="C"/>
			<xs:enumeration value="D"/>
			<xs:enumeration value="E"/>
			<xs:enumeration value="F"/>
			<xs:enumeration value="G"/>
			<xs:enumeration value="ND"/>
			<xs:enumeration value="Unknown"/>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-BurnerControlCode">
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>unknown</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>on/off (gas and oil burners)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>modulating (gas and oil boilers)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>manual (solid fuel boilers)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="5">
				<xs:annotation>
					<xs:documentation>electrical (solid fuel boilers)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-EfficiencyTypeCode">
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>not gas or oil boiler</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>SEDBUK(2005)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>SEDBUK(2009)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>winter and summer</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-HeatSourceTypeCode">
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>CHP</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>boilers</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>heat pump</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>waste heat</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="5">
				<xs:annotation>
					<xs:documentation>geothermal</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-RoofTypeCode">
		<xs:restriction base="xs:string">
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>exposed roof</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>party ceiling</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="AirChangeRateMonth">
		<xs:restriction base="xs:string">
			<xs:enumeration value="Jan"/>
			<xs:enumeration value="Feb"/>
			<xs:enumeration value="Mar"/>
			<xs:enumeration value="Apr"/>
			<xs:enumeration value="May"/>
			<xs:enumeration value="Jun"/>
			<xs:enumeration value="Jul"/>
			<xs:enumeration value="Aug"/>
			<xs:enumeration value="Sep"/>
			<xs:enumeration value="Oct"/>
			<xs:enumeration value="Nov"/>
			<xs:enumeration value="Dec"/>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="HydroElecMonth">
		<xs:restriction base="xs:string">
			<xs:enumeration value="Jan"/>
			<xs:enumeration value="Feb"/>
			<xs:enumeration value="Mar"/>
			<xs:enumeration value="Apr"/>
			<xs:enumeration value="May"/>
			<xs:enumeration value="Jun"/>
			<xs:enumeration value="Jul"/>
			<xs:enumeration value="Aug"/>
			<xs:enumeration value="Sep"/>
			<xs:enumeration value="Oct"/>
			<xs:enumeration value="Nov"/>
			<xs:enumeration value="Dec"/>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="MainHeatingSystemsInteraction">
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>both main heating systems provide heat to the whole property</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>the main heating systems are separate and heat different parts of the property</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="SAP-VerticalPitch">
		<xs:annotation>
			<xs:documentation>-1 is for backwards compatibility only; do not use</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:integer">
			<xs:minInclusive value="-1"/>
			<xs:maxInclusive value="90"/>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="EmitterTemperatureCode">
		<xs:annotation>
			<xs:documentation>Depending on the heating system, the codes can be one of
  - unknown
  - over 45°C
  - over 35°C and less than or equal to 45°C
  - less than or equal to 35°C
or one of:
  -unknown
  - over 35°C
  - less than or equal to 35°C
</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="0">
				<xs:annotation>
					<xs:documentation>unknown</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>over 45°C</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>over 35°C</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>over 35°C and less than or equal to 45°C</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>less than or equal to 35°C</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="NA">
				<xs:annotation>
					<xs:documentation>not applicable for the heating system</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="PumpAge">
		<xs:restriction base="xs:string">
			<xs:enumeration value="0">
				<xs:annotation>
					<xs:documentation>unknown</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>2012 or earlier</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>2013 or later</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="PVConnectionCode">
		<xs:restriction base="xs:string">
			<xs:enumeration value="0">
				<xs:annotation>
					<xs:documentation>not applicable (FGHRS)</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>not connected to dwelling's electricity meter</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>connected to dwelling's electricity meter</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="PipeworkInsulationCode">
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>not insulated</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>first 1 metre from cylinder insulated</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>all accessible pipework insulated</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>fully insulated</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="ShowerOutletTypeCode">
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>Vented hot water system</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>Vented hot water system + pump</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>Unvented hot water system</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>Instantaneous electric shower</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="5">
				<xs:annotation>
					<xs:documentation>Part G 2015 compliant</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="ShowerWWHRSCode">
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>none</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>Instantaneous WWHRS 1</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>Instantaneous WWHRS 2</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>Storage WWHRS</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="ServiceProvisionCode">
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>space and water heating</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>space heating only</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>water heating only</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>	
	<xs:simpleType name="Percentage">
		<xs:restriction base="xs:decimal">
			<xs:maxInclusive value="100"/>
			<xs:minInclusive value="0"/>
		</xs:restriction>
	</xs:simpleType>
	<xs:element name="Money" type="Money"/>
	<xs:complexType name="Money">
		<xs:annotation>
			<xs:documentation>Extension of a Decimal value for use with monetary values where a currency code needs to
be specified. 

The currency code is actually metadata about the value so, in line with good XML practice, the Currency Code is declared as an XML-Attribute of the Money datatype rather than as a separate XML-Element.

The currency attribute should then include a list of valid currencies codes that are supported.
</xs:documentation>
		</xs:annotation>
		<xs:simpleContent>
			<xs:extension base="xs:decimal">
				<xs:attribute name="currency" type="xs:string" use="optional"/>
			</xs:extension>
		</xs:simpleContent>
	</xs:complexType>
	<xs:simpleType name="Count">
		<xs:annotation>
			<xs:documentation>A count of the number of occurrences of something - must therefore be &gt;=0. This is the functional equivalent of the XML nonNegativeInteger datatype.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:nonNegativeInteger"/>
	</xs:simpleType>
	<xs:simpleType name="NonZeroCount">
		<xs:restriction base="xs:positiveInteger"/>
	</xs:simpleType>
	<xs:simpleType name="Measurement">
		<xs:annotation>
			<xs:documentation>A measurement of something such as a length or area. All measurements are to 2 decimal places and must be positive.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:decimal"/>
	</xs:simpleType>
	<xs:element name="IDString" type="IDString"/>
	<xs:complexType name="IDString">
		<xs:annotation>
			<xs:documentation>A string containing a unique identifier for something.

The underlying assumption is that each instance of a class or entity will have a unique identifier assigned to it which can then be assigned to any referencing entity as a reference to the entity instance.

This is a very similar concept to XML ID datatype but is locally defined because of the need to extend the datatype with domain specific attributes.</xs:documentation>
		</xs:annotation>
		<xs:simpleContent>
			<xs:extension base="xs:string"/>
		</xs:simpleContent>
	</xs:complexType>
	<xs:simpleType name="Flag">
		<xs:annotation>
			<xs:documentation>The Boolean datatype is a redefinition of the XML Schema defined "Boolean". The XSD version is a logical True / False datatype whereas from a data processing perspective it is more likely to be a string based Y/N value. This could be seen as an Enumerated Domain but "Boolean" is so common that it makes more sense to be a base datatype.
</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="Y">
				<xs:annotation>
					<xs:documentation>Yes</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="N">
				<xs:annotation>
					<xs:documentation>No</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="LanguageCode">
		<xs:restriction base="xs:string">
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>English</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>Welsh</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="ExtendedBoolean">
		<xs:annotation>
			<xs:documentation>An extended boolean type that also allows 'unknown' as a value.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:token">
			<xs:enumeration value="false"/>
			<xs:enumeration value="true"/>
			<xs:enumeration value="unknown"/>
		</xs:restriction>
	</xs:simpleType>
	<xs:element name="Sentence" type="Sentence"/>
	<xs:complexType name="Sentence">
		<xs:annotation>
			<xs:documentation>String value with a language code for natural-language text.</xs:documentation>
		</xs:annotation>
		<xs:simpleContent>
			<xs:extension base="xs:string">
				<xs:attribute name="language" type="LanguageCode" use="optional">
					<xs:annotation>
						<xs:documentation>Identifies the language that the sentence is recorded in.</xs:documentation>
					</xs:annotation>
				</xs:attribute>
			</xs:extension>
		</xs:simpleContent>
	</xs:complexType>
	<xs:simpleType name="RRNType">
		<xs:annotation>
			<xs:documentation>The Report Reference Number is a 20-digit unique identifier assigned to each Report. 

It is formatted as five blocks of four digits i.e. 9999-9999-9999-9999-9999 and generated by an algorithm described in Appendix A "Report ID Generation" of Section 18 "Transformation Rules" of the Technical Standards.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:pattern value="[0-9]{4}-[0-9]{4}-[0-9]{4}-[0-9]{4}-[0-9]{4}"/>
		</xs:restriction>
	</xs:simpleType>
	<xs:simpleType name="PropertyTypeCode">
		<xs:annotation>
			<xs:documentation>Code which indicates the type of property.</xs:documentation>
		</xs:annotation>
		<xs:restriction base="xs:string">
			<xs:enumeration value="0">
				<xs:annotation>
					<xs:documentation>House</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="1">
				<xs:annotation>
					<xs:documentation>Bungalow</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="2">
				<xs:annotation>
					<xs:documentation>Flat</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="3">
				<xs:annotation>
					<xs:documentation>Maisonette</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
			<xs:enumeration value="4">
				<xs:annotation>
					<xs:documentation>Park home</xs:documentation>
				</xs:annotation>
			</xs:enumeration>
		</xs:restriction>
	</xs:simpleType>